Freedom from grid failures, diesel price spikes, and supply disruptions — your own reliable power, on demand
Enabling the transition from fossil fuel dependence to Sustainable Power Systems for Commercial and Industrial enterprises
₹25–30/kWh vs ₹7. Toxic fumes vs zero emissions. No SLA vs 98.5% uptime. The comparison is decisive.
| Parameter | 🔴 Diesel Generator | 🟢 PWRNXT BESS |
|---|---|---|
| Switching Latency | Seconds to minutes spool-up Critical | Sub-millisecond — PLCs never detect an outage Zero Transition |
| OPEX | ₹25–30/kWh all-in diesel LCOE | ₹7–8/kWh off-peak grid charging |
| Acoustic Impact | >85 dBA continuous noise Non-compliant | Near-silent operation Undetectable |
| Emissions | NOx, PM2.5, CO₂ at point of use | Zero local emissions |
| Maintenance | Frequent Oil changes, filter replacements, overhauls | Quarterly checks managed by PWRNXT |
| Fuel Price Risk | Exposure to diesel supply chain, quality and logistics risks | Fixed lease payments — zero exposure |
| ESG Alignment | Incompatible with net-zero Liability | Fully ESG and net-zero aligned Asset |
| Uptime Guarantee | No formal SLA | Contractual 98.5% uptime SLA |
We own the BESS. You pay one fixed quarterly lease. Your capital stays free, your balance sheet stays clean.
Your sector has specific risks. We've engineered a solution for every one of them.

A power blink costs lakhs in material waste and machine resets. BESS switches in under 10ms — your PLCs never know there was an outage.
Grid-to-battery in <1ms — PLCs never detect an outage.
Eliminate annual losses from material spoilage during DG spool-up.
Restore productivity lost to machinery resets after power events.

One power failure means spoiled inventory and regulatory liability. BESS keeps your cold chain unbroken — while cutting energy costs by up to 60%.
Continuous power guarantees inventory never breaches temperature thresholds.
Charge off-peak at ₹7/kWh, discharge during peak windows — slashing demand charges.
Multi-value stacking delivers a significantly lower Levelised Cost of Energy.

Years of research, destroyed in one power blink. BESS paired with rooftop solar delivers a fully autonomous, zero-disruption campus grid.
Integrate with rooftop solar for a fully autonomous, renewable campus grid.
Protect multi-year experiments and high-value analytical equipment.
Operating lease fits fixed academic budgets while meeting sustainability mandates.

Life-support has zero tolerance for gaps. BESS switches in under 10ms — silent, emission-free, and invisible to every critical system.
BESS takes load instantly, extending backup autonomy beyond your existing UPS.
Eradicate NOx and PM2.5 near patient recovery zones and air intake systems.
75 dB vs >85 dBA for DG — protecting the acoustic environment for patients.

Diesel roar breaks the spell your guests pay for. BESS is invisible, silent, and emission-free — and it elevates your eco credentials.
Replace >85 dBA diesel roar with near-silent solid-state BESS operation.
Verifiable, emission-free backup power resonates with eco-conscious high-net-worth guests.
Zero transition — no lights flickering, no AC dropping, no disruption. Ever.

Simultaneous fast charging causes grid penalties and infrastructure bottlenecks. A 125kW BESS cabinet absorbs peak load instantly — zero penalties, no grid upgrade needed.
BESS instantly absorbs excess draw the moment EV demand breaches the sanctioned grid limit — zero penalty charges.
Service more vehicles at full speed without costly grid upgrades or capacity enhancement work.
Store excess rooftop solar generation and deliver 100% renewable energy directly to every EV.
We handle everything from design to go-live. Your team keeps running the business.
Data-backed techno-economic analysis: energy baseline, DG cost profiling, BESS sizing, site prioritisation, and phased implementation roadmap. Delivered within 6 weeks of data receipt.
Professional EngagementTailored architecture: LFP battery sizing, PCS matching, thermal and fire suppression management.
Engineering-LedFinalise operating lease terms, SLA covenants, performance guarantees, and exit provisions. Zero capex, fixed quarterly payments.
Off-Balance-SheetTurnkey EPC managed by PWRNXT Team.
100% TurnkeySite Acceptance Testing. System goes live only when every performance parameter is confirmed.
Certified CommissioningEMS-driven optimisation with 24/7 remote monitoring, predictive maintenance, and guaranteed <24hr on-site MTTR for critical faults.
98.5% Uptime SLANot a broker. Not a reseller. A fully integrated engineering operator with contractual skin in the game.
Custom sizing and architecture for every site — chemistry, PCS, thermal management, grid interface.
Tier-1 cell and inverter OEMs — CATL, BYD, Sungrow, Delta — with multi-year capacity warranties.
Proprietary EMS optimises every charge cycle against live tariffs and battery health in real time.
Pre-positioned critical spares at every site — so faults get fixed in hours, not days.
Every component is bankable, internationally certified, and chosen to outlast your lease.
Safety & Compliance Architecture
Each BESS deployment is engineered to meet rigorous international standards across every subsystem — from cell chemistry to grid interconnection — ensuring lender, insurer, and regulatory confidence.
Tier 1 Auto Ancillary, Haryana. 200 outages a year. ₹30/kWh diesel. Here's what happened after PWRNXT.
Monitoring is table stakes. We write performance into the contract.
Not a target. A contractual commitment — written into your lease, enforceable from day one.
On-site engineer response within 24 hours for critical faults. Critical spares pre-positioned at every site.
We flag degradation 2–4 weeks before it becomes a failure. Zero surprise downtime events.
Continuous State-of-Health analytics and automated anomaly alerts — across every PWRNXT asset in the field.
Send us your energy bills and DG logs. In 6 weeks, you'll know exactly what BESS will save you — site by site, rupee by rupee.
What we uncover for you
Optional add-on: Tender Preparation Advisory — technical spec ranges, commercial framework & site clustering for procurement.
How it happens — week by week
Send us your energy bills and DG logs. We'll scope a customised feasibility study and revert within 2 business days.